In
my last blog I have discussed about the lube oil supply unit for fans ,Air
heaters and Mills.
Construction features and item including control and
instrument in the lube oil system is
more less same .Therefore observing one
lube oil commissioning will help to learn the other.
Now
we will discuss the commissioning of FANS. The commissioning of six numbers of
FANs are similar however system requirement for commissioning of FANs are
different. We
will discuss the common system requirement and the individual
requirement of FANs.
Induced Draft Fan
No of Fan : 2
Flow (Approx) : 558.2 cu.m/Sec
Pressure (Approx) : 485 mmwc
Drive : Motor
Motor Rating : 3650
Control : Inlet Damper plus variable / Hydraulic coupling
Frequency Drive. (VFD).
Forced Draft Fan
No.
of Fan : 2
Flow (Approx) : 246
cu.m/Sec
Pressure (Approx) :
351 mmwc
Temperature : 50
degree C
Drive : Motor
Speed : 980 RPM
Control : Variable Blade Pitch control.
Motor
Rating :
1175 KW
The
boiler is also equipped with primary
air fan, which form a part of the coal preparation a
and firing system.
PRIMARY AIR FAN
No.
of Fan :
2
Flow (approx) :
170.5 cu.m/Sec
Pressure (approx) :
1183 mmwc
Temperature : 50
degreeC
Drive : Motor
Speed :
1480 RPM
Motor
Rating : 2450
KW.
Control :
Variable Blade Pitch
control.
All
the fan are mounted on concrete deck with suction and discharge duct. Connected
to the
Fan flanges. FD Fans and PA fans are provided with Silencer at the
suction duct.
Regulation of Fan from no
load to full load is performed by changing the pitch angle of blade
profile on
all blades simultaneously during operation. This is achieved through a
sophisticated servo mechanism (Hydraulic Servo Motor externally actuated by a
power
cylinder and forced lube-oil system.
In the case of ID Fan, the equipment
is driven by variable frequency drive motor coupled
with soft coupling. The
regulation of the fan is effected through the inlet dampers located at
the
inlet of the fan and variable speed by VFD.
In FD and PA fans, the rotor is
supported in antifriction bearings and
cooled by forced
lubricating oil. A thrust bearing is provided to absorb axial
loads. Thermometers (RTD &
TI ) are provided in the bearing housing for temperature monitoring.
In ID Fan, the bearings are while
metal sleeve type with forced oil lubrication. Fixed bearing
near drive end is
designed to absorb the Axial forces. Thermometers are provided in the b
earing
housing for temperature monitoring.
Respective O & M manuals to be
referred for typical drawing of each fan.
Common Facilities Required for Fans
before commissioning of the fans.
It
is proposed to commission the fans as per the following proposals.
Oil
flushing of lube-oil system is completed in all respect and fresh oil has been
filled in the tank.(****)
Trial
run of H.T. Motor carried out for 8 Hrs
as per agreed protocol.
Auxiliary
cooling water line connected ,flushed with all instrumentation and ready for
use.
LT
/HT Power supply available and Minimum protection is tested and ready.
Availability
of lighting, communication facility at the test area.
Servo
control mechanism / VFD system / Hydraulic coupling commissioned and
calibrated.
Instruments
for Pressure ,Temperature , Blade Pitch Position etc are commissioned and put
in place.