Total Pageviews

Friday 13 December 2013

ID,FD,PA FANS COMMISSIONING OF BOILER PART -X -ABC OFTHERMAL POWER


In my last blog I have discussed about the lube oil supply unit for fans ,Air heaters and Mills.
Construction features and item including control and instrument in the lube oil system is
more less same .Therefore observing one lube oil commissioning will help to learn the other.

Now we will discuss the commissioning of FANS. The commissioning of six numbers of
FANs are similar however system requirement for commissioning of FANs are different. We
will discuss the common system requirement and the individual requirement of FANs.


Induced Draft Fan



No of Fan                                :  2

Flow   (Approx)                       : 558.2 cu.m/Sec


Pressure (Approx)                  :  485 mmwc

Temperature                           :  1500C to 154 0C


Drive                                       :  Motor

Speed                                     :  580 RPM

Motor Rating                           :  3650

Control                                    :  Inlet Damper plus variable  / Hydraulic coupling

                                                   Frequency Drive. (VFD).

Forced Draft Fan



No. of Fan                                                   :  2
Flow    (Approx)                                          :  246 cu.m/Sec
Pressure    (Approx)                                    : 351 mmwc
Temperature                                               :  50 degree C
Drive                                                            : Motor
Speed                                                           : 980 RPM
Control                                                         : Variable Blade Pitch control.
Motor Rating                                               :  1175 KW

The boiler   is also equipped with primary air fan, which form a part of the coal preparation a
and firing system.
PRIMARY AIR FAN


 
No. of Fan                                               :  2
Flow       (approx)                                   :  170.5 cu.m/Sec
Pressure   (approx)                                 :  1183 mmwc
         
Temperature                                           :  50 degreeC
Drive                                                       :  Motor
Speed                                                      :  1480 RPM
Motor Rating                                          :  2450 KW.
Control                                                   :  Variable Blade Pitch
                                                                  control.
(****- All the values given here are of 500MW set of BHEL Make.)

 
All the fan are mounted on concrete deck with suction and discharge duct. Connected to the
Fan flanges. FD Fans and PA fans are provided with Silencer at the suction duct. 
Regulation of Fan from no load to full load is performed by changing the pitch angle of blade
profile on all blades simultaneously during operation. This is achieved through a
sophisticated servo mechanism (Hydraulic Servo Motor externally actuated by a power
cylinder and forced lube-oil system.
In the case of ID Fan, the equipment is driven by variable frequency drive motor coupled
with soft coupling. The regulation of the fan is effected through the inlet dampers located at
the inlet of the fan and variable speed by VFD.
In FD and PA fans, the rotor is supported in antifriction  bearings and cooled by forced
lubricating oil. A thrust bearing is provided to absorb axial loads. Thermometers (RTD &
TI ) are provided in the bearing housing for temperature monitoring.
In ID Fan, the bearings are while metal sleeve type with forced oil lubrication. Fixed bearing
near drive end is designed to absorb the Axial forces. Thermometers are provided in the b
earing housing for temperature monitoring.
Respective O & M manuals to be referred for typical drawing of each fan.
Common Facilities Required for Fans
Safety Rules clearance certificate to be signed at site by all concerned engineers

before commissioning of the fans.
 
It is proposed to commission the fans as per the following proposals.


Oil flushing of lube-oil system is completed in all respect and fresh oil has been filled in the tank.(****)

 (***)- Presently using electronic centrifuge flushing oil can be cleaned up to required
parameter and can be reused as fresh oil. 

Trial run of H.T. Motor carried out for  8 Hrs as per agreed protocol.

Auxiliary cooling water line connected ,flushed with all instrumentation and ready for use.

LT /HT Power supply available and Minimum protection is tested and ready.

Availability of lighting, communication facility at the test area.

 Availability of portable fire extinguishers

Servo control mechanism / VFD system / Hydraulic coupling commissioned and calibrated.

Instruments for Pressure ,Temperature , Blade Pitch Position etc are commissioned and put
in place.


 P.S If  you are looking to earn few legitimate extra money from the comfort of your home then please click on the link given below

LINK 1 - PLEASE CLICK HERE 
LINK 2 - PLEASE CLICK HERE




 



1 comment:

  1. Nice Post!
    If you have more specific services related to Turbine engine repair, maintenance and installation, please feel free to contact at @ nconturbines.com.

    ReplyDelete